CCH-SR safety relay module
The SRB safety relay module meets the EN/ISO 13849-1 Cat.4/PL e safety requirements and is suitable for monitoring the switching signals of safety light curtains in industrial fields with high safety requirements.
Product Category:
CCH-SR safety relay module
Keywords:
Type ENT safety light curtain
YB-type LiDAR
Details
Parameters
Specifications
Size
Install
Download
Product Features
1. Features two normally open contacts and one normally closed auxiliary contact; can achieve suppression and shielding functions
2. Allows selection of manual or automatic reset
3. Full-circuit self-check function, locking the signal when the two signals are inconsistent
4. Monitors two transistor signals - safety light curtain
5. Can monitor NPN/PNP signals, applicable to a wider range of environments
6. Reverse polarity protection design for power supply
7. Intuitive status indicator lights for easy operation status diagnosis
8. Detachable terminal blocks for easy maintenance
9. Standard 35mm width DIN rail mounting design
Specifications

Typical Wiring Diagram
Function Block Diagram

SRB-2A1B Wiring Diagram for Safety Light Curtain Automatic Reset (Internal Part)

Automatic Reset Wiring Diagram
Note:
1) OSSD1, OSSD2: OSSD signals are the signals output by the receiver when the safety light curtain operating mode is PNP or NPN.
2) After OSSD1 and OSSD2 are connected to S12 and S22 respectively, the DIP switch controls the selected mode (PNP/NPN) of the safety relay module to be the same as the OSSD signal type (PNP/NPN) of the safety light curtain output.
3) Automatic reset: Connecting SRC and SR with a wire enables the automatic reset function of the safety relay module.
SRB-2A1B Wiring Diagram for Safety Light Curtain Manual Reset (Internal Part)
Manual Reset Wiring Diagram

Note:
1) OSSD1, OSSD2: The relevant introduction and wiring method of OSSD(s) are consistent with those described in the automatic reset wiring.
2) Manual reset: Connecting both ends of the switch to SR and SRC enables manual control of the reset of the safety relay module.
MUT Wiring Diagram for Shielding Safety Light Curtain Signals
Shielding Light Curtain Signal Wiring

Note:
When the safety relay module is normally powered, connecting MUT_H to the 24V power supply and MUT_L to 0V puts the safety relay module in the shielding state. In this state, the safety light curtain signal cannot affect the safety relay module, and CH1, CH2, and the POWER light will remain on.
|
Electrical Parameters |
|
|
Operating Voltage |
DC24V±10% |
|
Rated Power |
<3W |
|
Response Time |
<10ms |
|
Attraction Buffer Time |
<50ms |
|
Power-on Startup Time |
<1s |
|
Safety Input |
Dual NPN input or dual PNP input |
|
Safety Output |
2 normally open passive contacts, 1 normally closed passive contact |
|
Relay Life |
≥1 million times (electrical life) |
|
Contact Capacity |
AC15:5A/250V |
|
DC13:6A/24V |
|
|
Environment |
|
|
Operating Temperature |
-30~50℃ (no frost or condensation) |
|
Storage Temperature |
-40~70℃ |
|
Operating Humidity |
35~85%RH |
|
Storage Humidity |
35~95%RH |
|
Protection Level |
IP20 |
|
Appearance Dimensions |
114.5mm×99.5mm×22.5mm |
|
Vibration Resistance |
Frequency: 5Hz~55Hz; Amplitude: 0.35±0.05mm; |
|
Scanning times: 20 times for each of the XYZ axes |
|
|
Impact Resistance |
Acceleration 10g, pulse duration 16ms |
|
Impact direction: 1000 times for each of the XYZ axes |
|
|
Standard Grade |
|
|
Safety Certification |
Performance Level (PL): PLe Complies with standard EN ISO 13849 |
|
Safety Category (Cat.): Cat.4 Complies with standard EN ISO 13849 |
|
|
Safety Integrity Level (SIL): SIL3 Complies with standards IEC 61508, IEC 62061 |
|
|
EMC |
Complies with EN61000-4-2:2009 EN61000-4-3:2006+A1:2009+A2:2010 EN61000-4-4:2004+A1:2010 EN61000-4-6:2014 EN61000-4-8:2010 |

Related Products
The SH series of deep-sea safety laser scanners is a high-performance single-line laser scanner based on the direct time-of-flight (dTOF) ranging principle. This product meets the high-level safety requirements of Type 3 (IEC 61496), SIL2 (IEC 61508), Cat. 3 (ISO 13849-1), and PL d (ISO 13849-1). It establishes definable protection zones using an invisible laser beam to protect hazardous areas, enabling protection of hazardous operating points, passageways, or hazardous areas of racks.
The ENT safety light curtain is TÜV certified and achieves safety levels of Type4, Cat.4, PLe, and SIL 3. It uses optical synchronous communication, features a compact and elegant design, and offers superior performance. Suitable for safety protection in hazardous environments within the automation field, such as mechanical presses, hydraulic presses, shearing machines, and bending machines.
The Yuanbao series LiDAR is a single-line LiDAR based on the dToF (direct Time-of-Flight) ranging principle. It features a compact size, ease of use, high precision, and high cost-effectiveness, making it suitable for diverse applications such as navigation and obstacle avoidance, and area monitoring.
The KH150-30ETH series solid-state LiDAR is a LiDAR system that does not contain any mechanically moving parts. Its operating principle is based on Optical Phased Array (OPA) technology and beam steering technology. It uses electronic control to direct and scan the laser beam, thereby achieving environmental detection.
Online Message